{"id":"57f3ce3689565b192797e00462991810af12ee4c74a39617544b759deb62143e","title":"Alain de Cheveigné’s arXiv paper proposes data-driven active magnetic shielding","argument":"In his arXiv paper, Alain de Cheveigné describes a way to reduce environmental magnetic fields that interfere with measurements such as magnetoencephalography (MEG), which measures magnetic fields arising within the brain. In feed-forward shielding, coils are driven by sensors measuring the uncorrected field. But the coils can couple to those reference sensors, making the approach harder to implement. De Cheveigné proposes using a data-driven “decoupling matrix” to suppress that coupling, with the aim of enabling effective shielding across a wide frequency range.\n\nThe paper evaluates the method by simulation, first in a simplified “flat world” and then using the geometry of a standard MEG system. De Cheveigné reports that performance appears limited only by spatial sampling and numerical resolution. The approach does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is described as complementary with standard feed-back shielding methods.\n\nThe proposal is especially relevant to optically-pumped magnetometers (OPM), which the paper says have lower cost and reduced constraints relative to SQUID-based systems. The author argues that those advantages create an incentive to reduce the cost and constraints of shielding too. The evaluation is simulation-based; the supplied evidence does not report performance in a physical MEG system.","topicIds":["intelligence-and-discovery"],"domain":"science","claimType":"attributed reading","limits":"The described evaluation is by simulation; the supplied evidence does not report performance in a physical MEG system. The abstract does not provide quantitative performance results or details of the simulation beyond the simplified “flat world” and standard MEG system geometry.","speaker":{"name":"de Cheveigné, Alain","roleAtSource":"Article author"},"source":{"title":"Feed-forward active magnetic shielding","publisher":"arXiv q-bio.NC","format":"Article","url":"https://arxiv.org/abs/2406.14234","publishedAt":"2024-06-20","dateBasis":"Date basis not provided."},"evidence":[{"text":"Alain de Cheveigné says feed-forward shielding uses coils driven by sensors measuring the uncorrected magnetic field, but coupling between coils and reference sensors complicates implementation.","excerpt":"In feed-forward shielding (less common), coils are driven from sensors that measure the uncorrected field. The latter has the potential of providing better performance, but its implementation is hobbled by an inevitable coupling between coils and reference sensors.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The paper proposes a data-driven decoupling matrix to suppress coil-to-sensor coupling and enable effective shielding across a wide frequency range.","excerpt":"employs a data-driven ``decoupling matrix\" to suppress the coupling, enabling greater flexibility to achieve effective shielding across a wide frequency range.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The author evaluates the method in simulation, including with the geometry of a standard MEG system, and says performance appears limited by spatial sampling and numerical resolution.","excerpt":"The method is evaluated by simulation, first using a simplified \"flat world\" in which the principle is clearly visualised, and then based on the more realistic geometry of a standard MEG system. Performance appears to be limited only by spatial sampling and numerical resolution.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The author says the method does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is complementary with standard feed-back shielding methods.","excerpt":"The method, which is data-driven and does not require geometric calculations, tight-tolerance fabrication, or manual calibration, is complementary with standard feed-back shielding methods.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The paper links interest in active shielding to optically-pumped magnetometers, saying their lower cost and reduced constraints relative to SQUID-based systems create an incentive to reduce shielding costs and constraints as well.","excerpt":"Active shielding is of particular interest in the context of a new generation of optically-pumped magnetometers (OPM), as the lower cost and reduced constraints of these new systems relative to SQUID-based systems provide an incentive to likewise reduce the cost and constraints of shielding.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2406.14234","checkedAt":"2026-11-10T07:48:08.503Z","items":[],"note":"No suitable media was found by the supported page extraction."},"assumptions":[],"openQuestion":{"attribution":"Open question","text":"How does the proposed method perform when implemented in a physical MEG system?"},"whatWouldChangeView":{"attribution":"Change condition not recorded","text":""},"editorialComparisons":[],"live":{"title":"Alain de Cheveigné’s arXiv paper proposes data-driven active magnetic shielding","summary":"In his arXiv paper, Alain de Cheveigné describes a way to reduce environmental magnetic fields that interfere with measurements such as magnetoencephalography (MEG), which measures magnetic fields arising within the brain. In feed-forward shielding, coils are driven by sensors measuring the uncorrected field. But the coils can couple to those reference sensors, making the approach harder to implement. De Cheveigné proposes using a data-driven “decoupling matrix” to suppress that coupling, with the aim of enabling effective shielding across a wide frequency range.\n\nThe paper evaluates the method by simulation, first in a simplified “flat world” and then using the geometry of a standard MEG system. De Cheveigné reports that performance appears limited only by spatial sampling and numerical resolution. The approach does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is described as complementary with standard feed-back shielding methods.\n\nThe proposal is especially relevant to optically-pumped magnetometers (OPM), which the paper says have lower cost and reduced constraints relative to SQUID-based systems. The author argues that those advantages create an incentive to reduce the cost and constraints of shielding too. The evaluation is simulation-based; the supplied evidence does not report performance in a physical MEG system.","question":"How does the proposed method perform when implemented in a physical MEG system?","claims":[{"text":"Alain de Cheveigné says feed-forward shielding uses coils driven by sensors measuring the uncorrected magnetic field, but coupling between coils and reference sensors complicates implementation.","excerpt":"In feed-forward shielding (less common), coils are driven from sensors that measure the uncorrected field. The latter has the potential of providing better performance, but its implementation is hobbled by an inevitable coupling between coils and reference sensors.","support":"source-stated"},{"text":"The paper proposes a data-driven decoupling matrix to suppress coil-to-sensor coupling and enable effective shielding across a wide frequency range.","excerpt":"employs a data-driven ``decoupling matrix\" to suppress the coupling, enabling greater flexibility to achieve effective shielding across a wide frequency range.","support":"source-stated"},{"text":"The author evaluates the method in simulation, including with the geometry of a standard MEG system, and says performance appears limited by spatial sampling and numerical resolution.","excerpt":"The method is evaluated by simulation, first using a simplified \"flat world\" in which the principle is clearly visualised, and then based on the more realistic geometry of a standard MEG system. Performance appears to be limited only by spatial sampling and numerical resolution.","support":"source-stated"},{"text":"The author says the method does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is complementary with standard feed-back shielding methods.","excerpt":"The method, which is data-driven and does not require geometric calculations, tight-tolerance fabrication, or manual calibration, is complementary with standard feed-back shielding methods.","support":"source-stated"},{"text":"The paper links interest in active shielding to optically-pumped magnetometers, saying their lower cost and reduced constraints relative to SQUID-based systems create an incentive to reduce shielding costs and constraints as well.","excerpt":"Active shielding is of particular interest in the context of a new generation of optically-pumped magnetometers (OPM), as the lower cost and reduced constraints of these new systems relative to SQUID-based systems provide an incentive to likewise reduce the cost and constraints of shielding.","support":"source-stated"}],"limitations":["The described evaluation is by simulation; the supplied evidence does not report performance in a physical MEG system.","The abstract does not provide quantitative performance results or details of the simulation beyond the simplified “flat world” and standard MEG system geometry."],"mediaId":"10f89a744a10d5fd2b2650adf8283edf789aa885329660ad8f3b1fdfc9c7128c","correctionReason":null,"id":"57f3ce3689565b192797e00462991810af12ee4c74a39617544b759deb62143e","publicationId":"8a0665c7-bc44-46d7-8b6c-6f904b48a3fb","version":1,"sourceUrl":"https://arxiv.org/abs/2406.14234","sourceTitle":"Feed-forward active magnetic shielding","publisher":"arXiv q-bio.NC","publishedAt":null,"originalPublished":{"value":"2024-06-20","precision":"day","basis":"publisher_citation_date"},"firstObservedAt":"2026-11-03T08:51:22.406Z","createdAt":"2026-11-10T07:32:55.417Z","historical":true,"entityIds":["arxiv"],"topicIds":["intelligence-and-discovery"],"media":[{"id":"10f89a744a10d5fd2b2650adf8283edf789aa885329660ad8f3b1fdfc9c7128c","kind":"article","url":"https://arxiv.org/abs/2406.14234","sourceUrl":"https://arxiv.org/abs/2406.14234","label":"Read original","provenance":"source_link","verification":{"status":"verified","checkedAt":"2026-11-03T17:34:49.429Z","method":"acquired_source","contentType":"text/html"},"recommendationReason":"Recommended by Jev for understanding this source; checked by Luna."}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2406.14234","checkedAt":"2026-11-10T07:48:08.503Z","items":[],"note":"No suitable media was found by the supported page extraction."},"editorialDecision":{"outcome":"accept","reasonCodes":["material_development"],"rubricVersion":"stream-admission-v5","mediaId":"10f89a744a10d5fd2b2650adf8283edf789aa885329660ad8f3b1fdfc9c7128c","confidence":0.54,"provider":"typesafe","model":"jev-1.13.0","inputHash":"6b93949eeb5db624d096f84f89fe163f7986623ddbfdfba8322196f30e7642ff","decidedAt":"2026-11-03T17:34:52.863Z","redecided":{"from":"stream-admission-v5","under":"stream-admission-v5+confidence-0.5"}},"provenance":{"textHash":"3ab20e6e39bfaa6fd2c6ffe58b29676d6a55885e8b254c6af22da261d817f3d2","observationId":"aefe99e81039d34813d8ba29bd654e5faf4c4fafe243f309c9e4a7aed2fae757","retrievedAt":"2026-11-03T17:34:48.928Z","kind":"publisher-page","preparer":{"model":"gpt-6-luna","runId":"753c99f5-4ad0-4138-8b7e-6a6b4b777096"},"reviewer":{"model":"gpt-6-luna","runId":"cb5849f3-942f-42b0-80de-105a9235246d"}},"audit":{"status":"uncertain","reviewedAt":"2026-11-10T07:32:55.417Z","model":"anthropic/claude-opus-5.5"},"sourceAttribution":{"authors":[{"name":"de Cheveigné, Alain","url":null,"kind":"unknown"}],"authorRole":"article-author","hosts":[],"status":"stated","authorRoster":{"truncated":false,"omitted":0,"assertionGroupsOmitted":0},"participation":[{"actor":{"name":"de Cheveigné, Alain","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"de Cheveigné, Alain","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2406.14234","locator":"head/meta[name=author|citation_author]"},"assertionId":"391ae449bef2828663f5d38ab0238ae15a87eadba4d88e0afaaaf10ca1d1bddb:participation:0","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-10T07:48:08.503Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"391ae449bef2828663f5d38ab0238ae15a87eadba4d88e0afaaaf10ca1d1bddb","sourceUrl":"https://arxiv.org/abs/2406.14234","contentSha256":"012dd7de268f79006d3ce9dac531c0849d93e0a6a63d71c77c6d63db995112d6","textHash":"3ab20e6e39bfaa6fd2c6ffe58b29676d6a55885e8b254c6af22da261d817f3d2","observedAt":"2026-11-10T07:48:08.503Z"}}],"participationCoverage":{"total":1,"returned":1,"complete":true,"fullAssertions":"source-metadata-endpoint"},"distribution":null,"publisher":null,"sourceUrl":"https://arxiv.org/abs/2406.14234","snapshotId":"391ae449bef2828663f5d38ab0238ae15a87eadba4d88e0afaaaf10ca1d1bddb","contentSha256":"012dd7de268f79006d3ce9dac531c0849d93e0a6a63d71c77c6d63db995112d6","textHash":"3ab20e6e39bfaa6fd2c6ffe58b29676d6a55885e8b254c6af22da261d817f3d2","observedAt":"2026-11-10T07:48:08.503Z","basis":"publisher-page-metadata","sourceLinks":49,"linksTruncated":false,"metadataUrl":"/api/pipeline/stream/57f3ce3689565b192797e00462991810af12ee4c74a39617544b759deb62143e/source"}},"canonicalUrl":"https://escapemeridian.com/readings/alain-de-cheveigne-s-arxiv-paper-proposes-data-driven-active-57f3ce36","formats":{"html":"/readings/alain-de-cheveigne-s-arxiv-paper-proposes-data-driven-active-57f3ce36","markdown":"/readings/alain-de-cheveigne-s-arxiv-paper-proposes-data-driven-active-57f3ce36.md","json":"/readings/alain-de-cheveigne-s-arxiv-paper-proposes-data-driven-active-57f3ce36.json"},"attribution":"Headline and summary by Escape Meridian, prepared by Luna from the attributed source. A source check is not independent confirmation of the source’s claims.","maintainedGuideLinks":[],"readerContext":{"version":"reader-context-v1","attribution":"Reference context selected by Escape Meridian; separate from source evidence. Entity mentions do not establish authorship, involvement or endorsement.","terms":[],"entities":[{"id":"arxiv","name":"arXiv","kind":"organization","context":"arXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.","referenceUrls":["https://arxiv.org/","https://info.arxiv.org/help/api/index.html"],"path":"/entities/arxiv","json":"/entities/arxiv.json","markdown":"/entities/arxiv.md"}]},"researchQuestions":[],"withdrawn":false,"references":{"schemaVersion":1,"target":{"type":"reading","id":"57f3ce3689565b192797e00462991810af12ee4c74a39617544b759deb62143e","revision":"8a0665c7-bc44-46d7-8b6c-6f904b48a3fb","revisionKind":"publication-id","title":"Alain de Cheveigné’s arXiv paper proposes data-driven active magnetic shielding","url":"https://escapemeridian.com/readings/alain-de-cheveigne-s-arxiv-paper-proposes-data-driven-active-57f3ce36"},"source":{"type":"source","id":"https://arxiv.org/abs/2406.14234","revision":"3ab20e6e39bfaa6fd2c6ffe58b29676d6a55885e8b254c6af22da261d817f3d2","revisionKind":"sha256-source-text","title":"Feed-forward active magnetic shielding","url":"https://arxiv.org/abs/2406.14234"},"status":"available","items":[],"next":null,"scope":"Explicit citations in public readings and public file attachments to this reading. Shared topics are not citations. Other artifact types need an explicit reference adapter."},"revisions":[{"id":"57f3ce3689565b192797e00462991810af12ee4c74a39617544b759deb62143e","title":"Alain de Cheveigné’s arXiv paper proposes data-driven active magnetic shielding","argument":"In his arXiv paper, Alain de Cheveigné describes a way to reduce environmental magnetic fields that interfere with measurements such as magnetoencephalography (MEG), which measures magnetic fields arising within the brain. In feed-forward shielding, coils are driven by sensors measuring the uncorrected field. But the coils can couple to those reference sensors, making the approach harder to implement. De Cheveigné proposes using a data-driven “decoupling matrix” to suppress that coupling, with the aim of enabling effective shielding across a wide frequency range.\n\nThe paper evaluates the method by simulation, first in a simplified “flat world” and then using the geometry of a standard MEG system. De Cheveigné reports that performance appears limited only by spatial sampling and numerical resolution. The approach does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is described as complementary with standard feed-back shielding methods.\n\nThe proposal is especially relevant to optically-pumped magnetometers (OPM), which the paper says have lower cost and reduced constraints relative to SQUID-based systems. The author argues that those advantages create an incentive to reduce the cost and constraints of shielding too. The evaluation is simulation-based; the supplied evidence does not report performance in a physical MEG system.","topicIds":["intelligence-and-discovery"],"domain":"science","claimType":"attributed reading","limits":"The described evaluation is by simulation; the supplied evidence does not report performance in a physical MEG system. The abstract does not provide quantitative performance results or details of the simulation beyond the simplified “flat world” and standard MEG system geometry.","speaker":{"name":"de Cheveigné, Alain","roleAtSource":"Article author"},"source":{"title":"Feed-forward active magnetic shielding","publisher":"arXiv q-bio.NC","format":"Article","url":"https://arxiv.org/abs/2406.14234","publishedAt":"2024-06-20","dateBasis":"Date basis not provided."},"evidence":[{"text":"Alain de Cheveigné says feed-forward shielding uses coils driven by sensors measuring the uncorrected magnetic field, but coupling between coils and reference sensors complicates implementation.","excerpt":"In feed-forward shielding (less common), coils are driven from sensors that measure the uncorrected field. The latter has the potential of providing better performance, but its implementation is hobbled by an inevitable coupling between coils and reference sensors.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The paper proposes a data-driven decoupling matrix to suppress coil-to-sensor coupling and enable effective shielding across a wide frequency range.","excerpt":"employs a data-driven ``decoupling matrix\" to suppress the coupling, enabling greater flexibility to achieve effective shielding across a wide frequency range.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The author evaluates the method in simulation, including with the geometry of a standard MEG system, and says performance appears limited by spatial sampling and numerical resolution.","excerpt":"The method is evaluated by simulation, first using a simplified \"flat world\" in which the principle is clearly visualised, and then based on the more realistic geometry of a standard MEG system. Performance appears to be limited only by spatial sampling and numerical resolution.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The author says the method does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is complementary with standard feed-back shielding methods.","excerpt":"The method, which is data-driven and does not require geometric calculations, tight-tolerance fabrication, or manual calibration, is complementary with standard feed-back shielding methods.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"},{"text":"The paper links interest in active shielding to optically-pumped magnetometers, saying their lower cost and reduced constraints relative to SQUID-based systems create an incentive to reduce shielding costs and constraints as well.","excerpt":"Active shielding is of particular interest in the context of a new generation of optically-pumped magnetometers (OPM), as the lower cost and reduced constraints of these new systems relative to SQUID-based systems provide an incentive to likewise reduce the cost and constraints of shielding.","url":"https://arxiv.org/abs/2406.14234","relationship":"Source-stated"}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2406.14234","checkedAt":"2026-11-10T07:48:08.503Z","items":[],"note":"No suitable media was found by the supported page extraction."},"assumptions":[],"openQuestion":{"attribution":"Open question","text":"How does the proposed method perform when implemented in a physical MEG system?"},"whatWouldChangeView":{"attribution":"Change condition not recorded","text":""},"editorialComparisons":[],"live":{"title":"Alain de Cheveigné’s arXiv paper proposes data-driven active magnetic shielding","summary":"In his arXiv paper, Alain de Cheveigné describes a way to reduce environmental magnetic fields that interfere with measurements such as magnetoencephalography (MEG), which measures magnetic fields arising within the brain. In feed-forward shielding, coils are driven by sensors measuring the uncorrected field. But the coils can couple to those reference sensors, making the approach harder to implement. De Cheveigné proposes using a data-driven “decoupling matrix” to suppress that coupling, with the aim of enabling effective shielding across a wide frequency range.\n\nThe paper evaluates the method by simulation, first in a simplified “flat world” and then using the geometry of a standard MEG system. De Cheveigné reports that performance appears limited only by spatial sampling and numerical resolution. The approach does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is described as complementary with standard feed-back shielding methods.\n\nThe proposal is especially relevant to optically-pumped magnetometers (OPM), which the paper says have lower cost and reduced constraints relative to SQUID-based systems. The author argues that those advantages create an incentive to reduce the cost and constraints of shielding too. The evaluation is simulation-based; the supplied evidence does not report performance in a physical MEG system.","question":"How does the proposed method perform when implemented in a physical MEG system?","claims":[{"text":"Alain de Cheveigné says feed-forward shielding uses coils driven by sensors measuring the uncorrected magnetic field, but coupling between coils and reference sensors complicates implementation.","excerpt":"In feed-forward shielding (less common), coils are driven from sensors that measure the uncorrected field. The latter has the potential of providing better performance, but its implementation is hobbled by an inevitable coupling between coils and reference sensors.","support":"source-stated"},{"text":"The paper proposes a data-driven decoupling matrix to suppress coil-to-sensor coupling and enable effective shielding across a wide frequency range.","excerpt":"employs a data-driven ``decoupling matrix\" to suppress the coupling, enabling greater flexibility to achieve effective shielding across a wide frequency range.","support":"source-stated"},{"text":"The author evaluates the method in simulation, including with the geometry of a standard MEG system, and says performance appears limited by spatial sampling and numerical resolution.","excerpt":"The method is evaluated by simulation, first using a simplified \"flat world\" in which the principle is clearly visualised, and then based on the more realistic geometry of a standard MEG system. Performance appears to be limited only by spatial sampling and numerical resolution.","support":"source-stated"},{"text":"The author says the method does not require geometric calculations, tight-tolerance fabrication, or manual calibration, and is complementary with standard feed-back shielding methods.","excerpt":"The method, which is data-driven and does not require geometric calculations, tight-tolerance fabrication, or manual calibration, is complementary with standard feed-back shielding methods.","support":"source-stated"},{"text":"The paper links interest in active shielding to optically-pumped magnetometers, saying their lower cost and reduced constraints relative to SQUID-based systems create an incentive to reduce shielding costs and constraints as well.","excerpt":"Active shielding is of particular interest in the context of a new generation of optically-pumped magnetometers (OPM), as the lower cost and reduced constraints of these new systems relative to SQUID-based systems provide an incentive to likewise reduce the cost and constraints of shielding.","support":"source-stated"}],"limitations":["The described evaluation is by simulation; the supplied evidence does not report performance in a physical MEG system.","The abstract does not provide quantitative performance results or details of the simulation beyond the simplified “flat world” and standard MEG system geometry."],"mediaId":"10f89a744a10d5fd2b2650adf8283edf789aa885329660ad8f3b1fdfc9c7128c","correctionReason":null,"id":"57f3ce3689565b192797e00462991810af12ee4c74a39617544b759deb62143e","publicationId":"8a0665c7-bc44-46d7-8b6c-6f904b48a3fb","version":1,"sourceUrl":"https://arxiv.org/abs/2406.14234","sourceTitle":"Feed-forward active magnetic shielding","publisher":"arXiv q-bio.NC","publishedAt":null,"originalPublished":{"value":"2024-06-20","precision":"day","basis":"publisher_citation_date"},"firstObservedAt":"2026-11-03T08:51:22.406Z","createdAt":"2026-11-10T07:32:55.417Z","historical":true,"entityIds":["arxiv"],"topicIds":["intelligence-and-discovery"],"media":[{"id":"10f89a744a10d5fd2b2650adf8283edf789aa885329660ad8f3b1fdfc9c7128c","kind":"article","url":"https://arxiv.org/abs/2406.14234","sourceUrl":"https://arxiv.org/abs/2406.14234","label":"Read original","provenance":"source_link","verification":{"status":"verified","checkedAt":"2026-11-03T17:34:49.429Z","method":"acquired_source","contentType":"text/html"},"recommendationReason":"Recommended by Jev for understanding this source; checked by Luna."}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2406.14234","checkedAt":"2026-11-10T07:48:08.503Z","items":[],"note":"No suitable media was found by the supported page extraction."},"editorialDecision":{"outcome":"accept","reasonCodes":["material_development"],"rubricVersion":"stream-admission-v5","mediaId":"10f89a744a10d5fd2b2650adf8283edf789aa885329660ad8f3b1fdfc9c7128c","confidence":0.54,"provider":"typesafe","model":"jev-1.13.0","inputHash":"6b93949eeb5db624d096f84f89fe163f7986623ddbfdfba8322196f30e7642ff","decidedAt":"2026-11-03T17:34:52.863Z","redecided":{"from":"stream-admission-v5","under":"stream-admission-v5+confidence-0.5"}},"provenance":{"textHash":"3ab20e6e39bfaa6fd2c6ffe58b29676d6a55885e8b254c6af22da261d817f3d2","observationId":"aefe99e81039d34813d8ba29bd654e5faf4c4fafe243f309c9e4a7aed2fae757","retrievedAt":"2026-11-03T17:34:48.928Z","kind":"publisher-page","preparer":{"model":"gpt-6-luna","runId":"753c99f5-4ad0-4138-8b7e-6a6b4b777096"},"reviewer":{"model":"gpt-6-luna","runId":"cb5849f3-942f-42b0-80de-105a9235246d"}},"audit":{"status":"uncertain","reviewedAt":"2026-11-10T07:32:55.417Z","model":"anthropic/claude-opus-5.5"},"sourceAttribution":{"authors":[{"name":"de Cheveigné, Alain","url":null,"kind":"unknown"}],"authorRole":"article-author","hosts":[],"status":"stated","authorRoster":{"truncated":false,"omitted":0,"assertionGroupsOmitted":0},"participation":[{"actor":{"name":"de Cheveigné, Alain","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"de Cheveigné, Alain","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2406.14234","locator":"head/meta[name=author|citation_author]"},"assertionId":"391ae449bef2828663f5d38ab0238ae15a87eadba4d88e0afaaaf10ca1d1bddb:participation:0","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-10T07:48:08.503Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"391ae449bef2828663f5d38ab0238ae15a87eadba4d88e0afaaaf10ca1d1bddb","sourceUrl":"https://arxiv.org/abs/2406.14234","contentSha256":"012dd7de268f79006d3ce9dac531c0849d93e0a6a63d71c77c6d63db995112d6","textHash":"3ab20e6e39bfaa6fd2c6ffe58b29676d6a55885e8b254c6af22da261d817f3d2","observedAt":"2026-11-10T07:48:08.503Z"}}],"participationCoverage":{"total":1,"returned":1,"complete":true,"fullAssertions":"source-metadata-endpoint"},"distribution":null,"publisher":null,"sourceUrl":"https://arxiv.org/abs/2406.14234","snapshotId":"391ae449bef2828663f5d38ab0238ae15a87eadba4d88e0afaaaf10ca1d1bddb","contentSha256":"012dd7de268f79006d3ce9dac531c0849d93e0a6a63d71c77c6d63db995112d6","textHash":"3ab20e6e39bfaa6fd2c6ffe58b29676d6a55885e8b254c6af22da261d817f3d2","observedAt":"2026-11-10T07:48:08.503Z","basis":"publisher-page-metadata","sourceLinks":49,"linksTruncated":false,"metadataUrl":"/api/pipeline/stream/57f3ce3689565b192797e00462991810af12ee4c74a39617544b759deb62143e/source"}}}],"audits":[{"publicationId":"8a0665c7-bc44-46d7-8b6c-6f904b48a3fb","verdict":"uncertain","findings":[{"dimension":"attribution","status":"pass","explanation":"The draft attributes the paper and its claims to Alain de Cheveigné, the sole listed author, and keeps the claims framed as the paper's own statements. The evaluation and performance statements are attributed rather than presented as established fact.","excerpt":"Authors:Alain de Cheveigné"},{"dimension":"summary","status":"uncertain","explanation":"The reading is broadly faithful, but a general reader may struggle with central terms. OPM and SQUID-based systems are named without plain explanation, and coupling is not explained as coils disturbing their own reference sensors. The draft also drops the paper's stated motivation for active shielding: passive shielding's cost, bulk and limited effectiveness. That omission weakens the why-it-matters thread. Smallest repair: add that motivation, define OPM and SQUID as two kinds of MEG sensor, and add term-library tooltips for these terms.","excerpt":"A common solution is passive shielding, but its cost, bulk and limited effectiveness motivate the alternative approach of active shielding"},{"dimension":"date","status":"pass","explanation":"originalPublished 2024-06-20 matches the v1 submission date. The 2026 dates are a later revision (v3) and the feed entry.","excerpt":"[Submitted on 20 Jun 2024 (v1), last revised 1 Nov 2026 (this version, v3)]"},{"dimension":"support","status":"uncertain","explanation":"The claims are source-stated, and the limitation that the evaluation is simulation-only is fair. However, the sentence 'The proposal is especially relevant to optically-pumped magnetometers' narrows the source's scope. The paper says active shielding in general is of particular interest for OPMs, not specifically this decoupling-matrix proposal. Smallest repair: change it to 'The paper says active shielding is of particular interest for OPMs.' The question about physical-system performance follows legitimately from the evidence.","excerpt":"Active shielding is of particular interest in the context of a new generation of optically-pumped magnetometers (OPM)"},{"dimension":"media","status":"pass","explanation":"The selected media is the verified arXiv abstract page for this paper, which is the direct original source.","excerpt":null}],"createdAt":"2026-11-10T07:32:55.417Z","model":"anthropic/claude-opus-5.5"}],"correctionUrl":"https://escapemeridian.com/corrections/"}