{"id":"c762ab74f6c9c03204ad79f493a71a33525d97fedf08d2103c22af232b00de8c","title":"arXiv cs.AI: Benchmarking decision models against generative large language models on medical multiple-choice questions","argument":"Authors Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert and Jakob Nikolas Kather compare decision models with generative large language models on medical multiple-choice questions. Using 1,273 four-option MedQA questions under text-only conditions, they report higher accuracy for generative configurations, while decision models offer resource advantages. The authors also find that answers assigned probability scores of at least 0.90 still had error rates ranging from 1.71% to 12.77%. Agreement across repeated runs did not mean probability repeatability was equally stable. Their central point is that choosing a model for medical workflows involves more than peak accuracy: probability quality, repeatability, and the resources needed to detect and correct errors matter too. How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?","topicIds":["intelligence-and-discovery"],"domain":"science","claimType":"attributed reading","limits":"The comparison used text-only, four-option MedQA questions; the supplied evidence does not report how the results translate to actual medical workflows. The supplied page contains the abstract, not the full study methods or results, so it does not establish the settings behind each model comparison beyond what the abstract states.","speaker":{"name":"Freyer, Oscar, Glauert, Daniel, Hofmann, Moritz, Ostermann, Max, Gilbert, Stephen, Kather, Jakob Nikolas","roleAtSource":"Article author"},"source":{"title":"Benchmarking decision models against generative large language models on medical multiple-choice questions","publisher":"arXiv cs.AI","format":"Article","url":"https://arxiv.org/abs/2610.38448","publishedAt":"2026-10-28","dateBasis":"Date basis not provided."},"evidence":[{"text":"The authors compared 13 decision models and 15 generative large language model configurations, using 1,273 four-option MedQA questions under text-only conditions.","excerpt":"We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"},{"text":"Generative configurations had a higher reported accuracy range than decision models in this comparison.","excerpt":"Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"},{"text":"The authors report that high probability scores did not eliminate errors, and that answer agreement and probability repeatability differed.","excerpt":"error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"},{"text":"The authors argue model selection for medical workflows should consider accuracy, probability quality, repeatability, and resources for error detection and correction.","excerpt":"selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2610.38448","checkedAt":"2026-11-11T07:44:08.095Z","items":[],"note":"No suitable media was found by the supported page extraction."},"assumptions":[],"openQuestion":{"attribution":"Open question","text":"How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?"},"whatWouldChangeView":{"attribution":"Change condition not recorded","text":""},"editorialComparisons":[],"live":{"title":"arXiv cs.AI: Benchmarking decision models against generative large language models on medical multiple-choice questions","summary":"Authors Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert and Jakob Nikolas Kather compare decision models with generative large language models on medical multiple-choice questions. Using 1,273 four-option MedQA questions under text-only conditions, they report higher accuracy for generative configurations, while decision models offer resource advantages. The authors also find that answers assigned probability scores of at least 0.90 still had error rates ranging from 1.71% to 12.77%. Agreement across repeated runs did not mean probability repeatability was equally stable. Their central point is that choosing a model for medical workflows involves more than peak accuracy: probability quality, repeatability, and the resources needed to detect and correct errors matter too. How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?","question":"How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?","claims":[{"text":"The authors compared 13 decision models and 15 generative large language model configurations, using 1,273 four-option MedQA questions under text-only conditions.","excerpt":"We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions.","support":"source-stated"},{"text":"Generative configurations had a higher reported accuracy range than decision models in this comparison.","excerpt":"Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations.","support":"source-stated"},{"text":"The authors report that high probability scores did not eliminate errors, and that answer agreement and probability repeatability differed.","excerpt":"error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied.","support":"source-stated"},{"text":"The authors argue model selection for medical workflows should consider accuracy, probability quality, repeatability, and resources for error detection and correction.","excerpt":"selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.","support":"source-stated"}],"limitations":["The comparison used text-only, four-option MedQA questions; the supplied evidence does not report how the results translate to actual medical workflows.","The supplied page contains the abstract, not the full study methods or results, so it does not establish the settings behind each model comparison beyond what the abstract states."],"mediaId":"a9cdf2e6d9fb8b8c3df25fa2b8111e03606013b6fafc36b0c84e5510a1177bd7","correctionReason":null,"id":"c762ab74f6c9c03204ad79f493a71a33525d97fedf08d2103c22af232b00de8c","publicationId":"326d21b3-c9cb-490d-81f0-a80c4e56b5e9","version":1,"sourceUrl":"https://arxiv.org/abs/2610.38448","sourceTitle":"Benchmarking decision models against generative large language models on medical multiple-choice questions","publisher":"arXiv cs.AI","publishedAt":null,"originalPublished":{"value":"2026-10-28","precision":"day","basis":"publisher_citation_date"},"firstObservedAt":"2026-10-30T06:45:25.202Z","createdAt":"2026-11-11T06:40:22.765Z","historical":true,"entityIds":["arxiv"],"topicIds":["intelligence-and-discovery"],"media":[{"id":"a9cdf2e6d9fb8b8c3df25fa2b8111e03606013b6fafc36b0c84e5510a1177bd7","kind":"article","url":"https://arxiv.org/abs/2610.38448","sourceUrl":"https://arxiv.org/abs/2610.38448","label":"Read original","provenance":"source_link","verification":{"status":"verified","checkedAt":"2026-10-31T10:32:42.223Z","method":"acquired_source","contentType":"text/html"},"recommendationReason":"Recommended by Jev for understanding this source; checked by Luna."}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2610.38448","checkedAt":"2026-11-11T07:44:08.095Z","items":[],"note":"No suitable media was found by the supported page extraction."},"editorialDecision":{"outcome":"accept","reasonCodes":["material_development"],"rubricVersion":"stream-admission-v5","mediaId":"a9cdf2e6d9fb8b8c3df25fa2b8111e03606013b6fafc36b0c84e5510a1177bd7","confidence":0.8099999999999999,"provider":"typesafe","model":"jev-1.13.0","inputHash":"3b67de61f9be65a15664e0f24ddde28deca3987c31918f66e98ef751bf7a7476","decidedAt":"2026-10-31T10:32:42.722Z"},"provenance":{"textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observationId":"6ef6a4b4cfa05baface00292099cdc0191d810c411496a07cce4a241012357ad","retrievedAt":"2026-10-31T10:32:42.158Z","kind":"publisher-page","preparer":{"model":"gpt-6-luna","runId":"ea8f9169-02bf-42e1-82a4-c366c18b09d2"},"reviewer":{"model":"gpt-6-luna","runId":"63d6b764-7bbd-4223-88eb-d41b3cf8a38f"}},"audit":{"status":"uncertain","reviewedAt":"2026-11-11T06:40:22.765Z","model":"anthropic/claude-opus-5.5"},"sourceAttribution":{"authors":[{"name":"Freyer, Oscar","url":null,"kind":"unknown"},{"name":"Glauert, Daniel","url":null,"kind":"unknown"},{"name":"Hofmann, Moritz","url":null,"kind":"unknown"},{"name":"Ostermann, Max","url":null,"kind":"unknown"},{"name":"Gilbert, Stephen","url":null,"kind":"unknown"},{"name":"Kather, Jakob Nikolas","url":null,"kind":"unknown"}],"authorRole":"article-author","hosts":[],"status":"stated","authorRoster":{"truncated":false,"omitted":0,"assertionGroupsOmitted":0},"participation":[{"actor":{"name":"Freyer, Oscar","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Freyer, Oscar","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:0","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Glauert, Daniel","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Glauert, Daniel","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:1","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Hofmann, Moritz","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Hofmann, Moritz","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:2","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Ostermann, Max","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Ostermann, Max","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:3","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Gilbert, Stephen","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Gilbert, Stephen","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:4","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Kather, Jakob Nikolas","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Kather, Jakob Nikolas","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:5","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}}],"participationCoverage":{"total":6,"returned":6,"complete":true,"fullAssertions":"source-metadata-endpoint"},"distribution":null,"publisher":null,"sourceUrl":"https://arxiv.org/abs/2610.38448","snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z","basis":"publisher-page-metadata","sourceLinks":42,"linksTruncated":false,"metadataUrl":"/api/pipeline/stream/c762ab74f6c9c03204ad79f493a71a33525d97fedf08d2103c22af232b00de8c/source"}},"canonicalUrl":"https://escapemeridian.com/readings/arxiv-cs-ai-benchmarking-decision-models-against-generative-c762ab74","formats":{"html":"/readings/arxiv-cs-ai-benchmarking-decision-models-against-generative-c762ab74","markdown":"/readings/arxiv-cs-ai-benchmarking-decision-models-against-generative-c762ab74.md","json":"/readings/arxiv-cs-ai-benchmarking-decision-models-against-generative-c762ab74.json"},"attribution":"Headline and summary by Escape Meridian, prepared by Luna from the attributed source. A source check is not independent confirmation of the source’s claims.","maintainedGuideLinks":[],"readerContext":{"version":"reader-context-v1","attribution":"Reference context selected by Escape Meridian; separate from source evidence. Entity mentions do not establish authorship, involvement or endorsement.","terms":[{"id":"term-benchmark","name":"Benchmark","explanation":"A defined set of tests used to compare systems. Results depend on the tasks and measures selected.","referenceUrl":"https://arxiv.org/abs/2211.09110"},{"id":"term-llm","name":"Large language model","explanation":"A language model with many learned numerical settings, used to process and generate language.","referenceUrl":"https://developers.google.com/machine-learning/glossary#large-language-model"}],"entities":[{"id":"arxiv","name":"arXiv","kind":"organization","context":"arXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.","referenceUrls":["https://arxiv.org/","https://info.arxiv.org/help/api/index.html"],"path":"/entities/arxiv","json":"/entities/arxiv.json","markdown":"/entities/arxiv.md"}]},"researchQuestions":[],"withdrawn":false,"references":{"schemaVersion":1,"target":{"type":"reading","id":"c762ab74f6c9c03204ad79f493a71a33525d97fedf08d2103c22af232b00de8c","revision":"326d21b3-c9cb-490d-81f0-a80c4e56b5e9","revisionKind":"publication-id","title":"arXiv cs.AI: Benchmarking decision models against generative large language models on medical multiple-choice questions","url":"https://escapemeridian.com/readings/arxiv-cs-ai-benchmarking-decision-models-against-generative-c762ab74"},"source":{"type":"source","id":"https://arxiv.org/abs/2610.38448","revision":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","revisionKind":"sha256-source-text","title":"Benchmarking decision models against generative large language models on medical multiple-choice questions","url":"https://arxiv.org/abs/2610.38448"},"status":"available","items":[],"next":null,"scope":"Explicit citations in public readings and public file attachments to this reading. Shared topics are not citations. Other artifact types need an explicit reference adapter."},"revisions":[{"id":"c762ab74f6c9c03204ad79f493a71a33525d97fedf08d2103c22af232b00de8c","title":"arXiv cs.AI: Benchmarking decision models against generative large language models on medical multiple-choice questions","argument":"Authors Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert and Jakob Nikolas Kather compare decision models with generative large language models on medical multiple-choice questions. Using 1,273 four-option MedQA questions under text-only conditions, they report higher accuracy for generative configurations, while decision models offer resource advantages. The authors also find that answers assigned probability scores of at least 0.90 still had error rates ranging from 1.71% to 12.77%. Agreement across repeated runs did not mean probability repeatability was equally stable. Their central point is that choosing a model for medical workflows involves more than peak accuracy: probability quality, repeatability, and the resources needed to detect and correct errors matter too. How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?","topicIds":["intelligence-and-discovery"],"domain":"science","claimType":"attributed reading","limits":"The comparison used text-only, four-option MedQA questions; the supplied evidence does not report how the results translate to actual medical workflows. The supplied page contains the abstract, not the full study methods or results, so it does not establish the settings behind each model comparison beyond what the abstract states.","speaker":{"name":"Freyer, Oscar, Glauert, Daniel, Hofmann, Moritz, Ostermann, Max, Gilbert, Stephen, Kather, Jakob Nikolas","roleAtSource":"Article author"},"source":{"title":"Benchmarking decision models against generative large language models on medical multiple-choice questions","publisher":"arXiv cs.AI","format":"Article","url":"https://arxiv.org/abs/2610.38448","publishedAt":"2026-10-28","dateBasis":"Date basis not provided."},"evidence":[{"text":"The authors compared 13 decision models and 15 generative large language model configurations, using 1,273 four-option MedQA questions under text-only conditions.","excerpt":"We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"},{"text":"Generative configurations had a higher reported accuracy range than decision models in this comparison.","excerpt":"Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"},{"text":"The authors report that high probability scores did not eliminate errors, and that answer agreement and probability repeatability differed.","excerpt":"error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"},{"text":"The authors argue model selection for medical workflows should consider accuracy, probability quality, repeatability, and resources for error detection and correction.","excerpt":"selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.","url":"https://arxiv.org/abs/2610.38448","relationship":"Source-stated"}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2610.38448","checkedAt":"2026-11-11T07:44:08.095Z","items":[],"note":"No suitable media was found by the supported page extraction."},"assumptions":[],"openQuestion":{"attribution":"Open question","text":"How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?"},"whatWouldChangeView":{"attribution":"Change condition not recorded","text":""},"editorialComparisons":[],"live":{"title":"arXiv cs.AI: Benchmarking decision models against generative large language models on medical multiple-choice questions","summary":"Authors Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert and Jakob Nikolas Kather compare decision models with generative large language models on medical multiple-choice questions. Using 1,273 four-option MedQA questions under text-only conditions, they report higher accuracy for generative configurations, while decision models offer resource advantages. The authors also find that answers assigned probability scores of at least 0.90 still had error rates ranging from 1.71% to 12.77%. Agreement across repeated runs did not mean probability repeatability was equally stable. Their central point is that choosing a model for medical workflows involves more than peak accuracy: probability quality, repeatability, and the resources needed to detect and correct errors matter too. How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?","question":"How well do these differences carry over from text-only multiple-choice questions to actual medical workflows?","claims":[{"text":"The authors compared 13 decision models and 15 generative large language model configurations, using 1,273 four-option MedQA questions under text-only conditions.","excerpt":"We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions.","support":"source-stated"},{"text":"Generative configurations had a higher reported accuracy range than decision models in this comparison.","excerpt":"Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations.","support":"source-stated"},{"text":"The authors report that high probability scores did not eliminate errors, and that answer agreement and probability repeatability differed.","excerpt":"error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied.","support":"source-stated"},{"text":"The authors argue model selection for medical workflows should consider accuracy, probability quality, repeatability, and resources for error detection and correction.","excerpt":"selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.","support":"source-stated"}],"limitations":["The comparison used text-only, four-option MedQA questions; the supplied evidence does not report how the results translate to actual medical workflows.","The supplied page contains the abstract, not the full study methods or results, so it does not establish the settings behind each model comparison beyond what the abstract states."],"mediaId":"a9cdf2e6d9fb8b8c3df25fa2b8111e03606013b6fafc36b0c84e5510a1177bd7","correctionReason":null,"id":"c762ab74f6c9c03204ad79f493a71a33525d97fedf08d2103c22af232b00de8c","publicationId":"326d21b3-c9cb-490d-81f0-a80c4e56b5e9","version":1,"sourceUrl":"https://arxiv.org/abs/2610.38448","sourceTitle":"Benchmarking decision models against generative large language models on medical multiple-choice questions","publisher":"arXiv cs.AI","publishedAt":null,"originalPublished":{"value":"2026-10-28","precision":"day","basis":"publisher_citation_date"},"firstObservedAt":"2026-10-30T06:45:25.202Z","createdAt":"2026-11-11T06:40:22.765Z","historical":true,"entityIds":["arxiv"],"topicIds":["intelligence-and-discovery"],"media":[{"id":"a9cdf2e6d9fb8b8c3df25fa2b8111e03606013b6fafc36b0c84e5510a1177bd7","kind":"article","url":"https://arxiv.org/abs/2610.38448","sourceUrl":"https://arxiv.org/abs/2610.38448","label":"Read original","provenance":"source_link","verification":{"status":"verified","checkedAt":"2026-10-31T10:32:42.223Z","method":"acquired_source","contentType":"text/html"},"recommendationReason":"Recommended by Jev for understanding this source; checked by Luna."}],"sourceMedia":{"status":"not_found","sourceUrl":"https://arxiv.org/abs/2610.38448","checkedAt":"2026-11-11T07:44:08.095Z","items":[],"note":"No suitable media was found by the supported page extraction."},"editorialDecision":{"outcome":"accept","reasonCodes":["material_development"],"rubricVersion":"stream-admission-v5","mediaId":"a9cdf2e6d9fb8b8c3df25fa2b8111e03606013b6fafc36b0c84e5510a1177bd7","confidence":0.8099999999999999,"provider":"typesafe","model":"jev-1.13.0","inputHash":"3b67de61f9be65a15664e0f24ddde28deca3987c31918f66e98ef751bf7a7476","decidedAt":"2026-10-31T10:32:42.722Z"},"provenance":{"textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observationId":"6ef6a4b4cfa05baface00292099cdc0191d810c411496a07cce4a241012357ad","retrievedAt":"2026-10-31T10:32:42.158Z","kind":"publisher-page","preparer":{"model":"gpt-6-luna","runId":"ea8f9169-02bf-42e1-82a4-c366c18b09d2"},"reviewer":{"model":"gpt-6-luna","runId":"63d6b764-7bbd-4223-88eb-d41b3cf8a38f"}},"audit":{"status":"uncertain","reviewedAt":"2026-11-11T06:40:22.765Z","model":"anthropic/claude-opus-5.5"},"sourceAttribution":{"authors":[{"name":"Freyer, Oscar","url":null,"kind":"unknown"},{"name":"Glauert, Daniel","url":null,"kind":"unknown"},{"name":"Hofmann, Moritz","url":null,"kind":"unknown"},{"name":"Ostermann, Max","url":null,"kind":"unknown"},{"name":"Gilbert, Stephen","url":null,"kind":"unknown"},{"name":"Kather, Jakob Nikolas","url":null,"kind":"unknown"}],"authorRole":"article-author","hosts":[],"status":"stated","authorRoster":{"truncated":false,"omitted":0,"assertionGroupsOmitted":0},"participation":[{"actor":{"name":"Freyer, Oscar","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Freyer, Oscar","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:0","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Glauert, Daniel","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Glauert, Daniel","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:1","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Hofmann, Moritz","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Hofmann, Moritz","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:2","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Ostermann, Max","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Ostermann, Max","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:3","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Gilbert, Stephen","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Gilbert, Stephen","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:4","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}},{"actor":{"name":"Kather, Jakob Nikolas","url":null,"kind":"unknown","actorId":null},"role":"author","scope":{"kind":"work-credit","locator":null},"literalCredit":"Kather, Jakob Nikolas","status":"stated","provenance":{"basis":"head-meta","sourceUrl":"https://arxiv.org/abs/2610.38448","locator":"head/meta[name=author|citation_author]"},"assertionId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406:participation:5","identity":{"version":"entity-identity-v1","status":"unresolved","actorId":null,"canonicalActorId":null,"candidateActorIds":[],"assertions":[],"sourceObservedAt":"2026-11-11T07:44:08.095Z","knowledgeAsOf":null},"sourceVersion":{"snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","sourceUrl":"https://arxiv.org/abs/2610.38448","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z"}}],"participationCoverage":{"total":6,"returned":6,"complete":true,"fullAssertions":"source-metadata-endpoint"},"distribution":null,"publisher":null,"sourceUrl":"https://arxiv.org/abs/2610.38448","snapshotId":"67eee4745e1dfc96835aaf7d38a3a205dd3e4958e40a51b03f5d8a2d3a02d406","contentSha256":"c01131e72e4f885430f374ba95253608443f9ca8f730ce5ec68d4f83c4b2d0dc","textHash":"7506e53aa5b7b5457e7262d43884fa6f29fd884193bc69a8cf99a0cfaa145bca","observedAt":"2026-11-11T07:44:08.095Z","basis":"publisher-page-metadata","sourceLinks":42,"linksTruncated":false,"metadataUrl":"/api/pipeline/stream/c762ab74f6c9c03204ad79f493a71a33525d97fedf08d2103c22af232b00de8c/source"}}}],"audits":[{"publicationId":"326d21b3-c9cb-490d-81f0-a80c4e56b5e9","verdict":"uncertain","findings":[{"dimension":"attribution","status":"pass","explanation":"The reading correctly attributes the study to the six listed authors. It keeps the findings and the recommendation as the authors' reported results and argument, not as established fact.","excerpt":"Authors:Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert, Jakob Nikolas Kather"},{"dimension":"summary","status":"uncertain","explanation":"The central comparison depends on the term 'decision models', which is never explained against generative LLMs. MedQA and 'probability quality' are also unexplained. A lay reader cannot tell what kinds of systems are being compared; the abstract itself does not define them. Keep the terms and add tooltips, or state that the abstract does not define them. The question is also repeated verbatim at the end of the summary. Otherwise the reading faithfully conveys the authors' central point that peak accuracy alone is not enough.","excerpt":"Decision models offered resource advantages alongside lower peak accuracy"},{"dimension":"date","status":"pass","explanation":"originalPublished is 2026-10-28, which matches the arXiv v1 submission date. The feed date of Oct 31 is correctly not used.","excerpt":"[Submitted on 28 Oct 2026]"},{"dimension":"support","status":"uncertain","explanation":"The summary says the authors 'report higher accuracy for generative configurations.' The ranges overlap, however: the weakest generative configuration (78.32%) scored below the best decision model (89.08%). The abstract only claims lower peak accuracy for decision models. Smallest repair: say 'higher peak accuracy' or 'a higher accuracy range'. 'Agreement ... did not mean probability repeatability was equally stable' is a mild rephrasing of 'probability repeatability varied'. The remaining claims and limitations are grounded in the abstract.","excerpt":"Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations."},{"dimension":"media","status":"pass","explanation":"The selected media is the verified direct link to the arXiv abstract page, which is the original source.","excerpt":null}],"createdAt":"2026-11-11T06:40:22.765Z","model":"anthropic/claude-opus-5.5"}],"correctionUrl":"https://escapemeridian.com/corrections/"}