Qiu, Yiwen, Sun, Che, Shen, Shu, Wang, Wentao · Nov 20, 2026
arXiv cs.AI: Evidence sufficiency assessment for clinical AI review
Markdown · JSON · Original source
In their paper, Yiwen Qiu, Che Sun, Shu Shen and Wentao Wang propose a way to decide which clinical AI diagnoses can be accepted automatically and which should receive more computation or clinician review. Their training-free decision-point evidence sufficiency assessment uses objective evidence, rather than the model’s stated confidence, to choose among single-run, five-run consistency and full-deferral tiers. The authors report that, across the evaluated cases, the approach reached the clinical target with single-run results on MIRA-v2, matching five-run consistency while saving about 80% compute. CDM reached the test target after escalation to five-run consistency; the cross-specialty, missing-imaging, and combined enriched cohorts entered full deferral. The paper’s central idea is to spend more computation or require clinician review when evidence is insufficient, rather than treating confidence alone as a reason to accept a diagnosis. These are results reported in the paper’s abstract, not evidence here of performance in other clinical settings.
Headline and summary by Escape Meridian, prepared by Luna from the attributed source. A source check is not independent confirmation of the source’s claims.
Original source
cs.AI · Article
Source details
Original source date: Nov 20, 2026 (2026-11-20).
Date basis: Original submission date in the publisher’s citation record.
Added to Escape Meridian: 2026-11-23T07:48:31.507Z. First observed: 2026-11-23T05:07:22.823Z. Retrieved: 2026-11-23T07:47:17.038Z.
Referenced by
Recorded citations in public readings. A reference alone does not establish agreement or influence.
No public references recorded here yet.
Limits
The evidence provided is the abstract, not the full paper; it does not describe the detailed evaluation methods or give results broken down for each named cohort. The reported results concern the listed evaluated cases; the abstract does not establish performance in other clinical settings.
Open question
What evidence would show whether this triage approach meets its target in clinical settings beyond the evaluated cohorts?
Source-stated
The authors propose a training-free assessment using objective evidence to allocate cases among three review or computation tiers.
We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol.
Source-stated
The authors report that token probabilities and self-reported confidence miss errors, while five-run consistency costs five times as much compute.
token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute.
Source-stated
The method scores evidence sufficiency using the same 4B model, with reasoning and diagnosis masked, and prior-debiased probabilities over five ordered levels.
Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels.
Source-stated
The authors report MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency while saving about 80% compute.
MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute
Source-stated
The authors report CDM attained its test target by escalating to five-run consistency; other listed cohorts entered full deferral.
CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier
Source-stated
The abstract reports results across 1,605 cases from four named sources or cohorts.
Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases
Source and contributor context
Qiu, Yiwen, Sun, Che, Shen, Shu, Wang, Wentao · Article author
These are credits stated by the source; they do not establish a profile match or authorship of every passage.
Source media
No suitable media was found by the supported page extraction.
Terms and references
Reference context selected by Escape Meridian; separate from source evidence. Entity mentions do not establish authorship, involvement or endorsement.
arXiv
arXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.
Editorial provenance
Version 1. Publication ID: f2fc712b-aa33-46fa-8de6-f42a6e17bae3.
Prepared by gpt-6-luna; grounding review by gpt-6-luna.
Source check: uncertain by anthropic/claude-opus-5.5 on 2026-11-23T07:48:31.507Z. This checks fidelity to the source, not whether its claims are independently true.
Editorial selection: accept; reasons: material_development.
Observation: d3896c4e995aff0d8dbcec7e58ed7c89761d685dac7ca7f2fdfb06a85f6e46d1. Source text hash: 8783faa947a0cca4b6376dea2defba9c7abc94e3dfee3b606292d176938b06bb.
Revision and source-check history
Version 1 · 2026-11-23T07:48:31.507Z
arXiv cs.AI: Evidence sufficiency assessment for clinical AI review
In their paper, Yiwen Qiu, Che Sun, Shu Shen and Wentao Wang propose a way to decide which clinical AI diagnoses can be accepted automatically and which should receive more computation or clinician review. Their training-free decision-point evidence sufficiency assessment uses objective evidence, rather than the model’s stated confidence, to choose among single-run, five-run consistency and full-deferral tiers. The authors report that, across the evaluated cases, the approach reached the clinical target with single-run results on MIRA-v2, matching five-run consistency while saving about 80% compute. CDM reached the test target after escalation to five-run consistency; the cross-specialty, missing-imaging, and combined enriched cohorts entered full deferral. The paper’s central idea is to spend more computation or require clinician review when evidence is insufficient, rather than treating confidence alone as a reason to accept a diagnosis. These are results reported in the paper’s abstract, not evidence here of performance in other clinical settings.
Original source
cs.AI · Article
Source details
Original source date: Nov 20, 2026 (2026-11-20).
Date basis: Original submission date in the publisher’s citation record.
Added to Escape Meridian: 2026-11-23T07:48:31.507Z. First observed: 2026-11-23T05:07:22.823Z. Retrieved: 2026-11-23T07:47:17.038Z.
Limits
The evidence provided is the abstract, not the full paper; it does not describe the detailed evaluation methods or give results broken down for each named cohort. The reported results concern the listed evaluated cases; the abstract does not establish performance in other clinical settings.
Open question
What evidence would show whether this triage approach meets its target in clinical settings beyond the evaluated cohorts?
Source-stated
The authors propose a training-free assessment using objective evidence to allocate cases among three review or computation tiers.
We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol.
Source-stated
The authors report that token probabilities and self-reported confidence miss errors, while five-run consistency costs five times as much compute.
token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute.
Source-stated
The method scores evidence sufficiency using the same 4B model, with reasoning and diagnosis masked, and prior-debiased probabilities over five ordered levels.
Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels.
Source-stated
The authors report MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency while saving about 80% compute.
MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute
Source-stated
The authors report CDM attained its test target by escalating to five-run consistency; other listed cohorts entered full deferral.
CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier
Source-stated
The abstract reports results across 1,605 cases from four named sources or cohorts.
Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases
Source and contributor context
Qiu, Yiwen, Sun, Che, Shen, Shu, Wang, Wentao · Article author
These are credits stated by the source; they do not establish a profile match or authorship of every passage.
Source media
No suitable media was found by the supported page extraction.
Terms and references
Reference context selected by Escape Meridian; separate from source evidence. Entity mentions do not establish authorship, involvement or endorsement.
arXiv
arXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.
Editorial provenance
Version 1. Publication ID: f2fc712b-aa33-46fa-8de6-f42a6e17bae3.
Prepared by gpt-6-luna; grounding review by gpt-6-luna.
Source check: uncertain by anthropic/claude-opus-5.5 on 2026-11-23T07:48:31.507Z. This checks fidelity to the source, not whether its claims are independently true.
Editorial selection: accept; reasons: material_development.
Observation: d3896c4e995aff0d8dbcec7e58ed7c89761d685dac7ca7f2fdfb06a85f6e46d1. Source text hash: 8783faa947a0cca4b6376dea2defba9c7abc94e3dfee3b606292d176938b06bb.
uncertain · 2026-11-23T07:48:31.507Z · anthropic/claude-opus-5.5
Publication: f2fc712b-aa33-46fa-8de6-f42a6e17bae3
attribution — pass: The reading correctly attributes the paper to Yiwen Qiu, Che Sun, Shu Shen and Wentao Wang. It keeps the results framed as the authors' reported abstract results, not established facts.
Authors:Yiwen Qiu, Che Sun, Shu Shen, Wentao Wang
summary — uncertain: The reading is broadly faithful, but some central terms are left unexplained for a general reader. It does not say that five-run consistency means running the model five times and checking agreement. MIRA-v2 and CDM appear without saying they are evaluation datasets. It also omits the on-premise setting and the reported 0.00%-3.50% cap on the calibration false-certification rate, a key safety result. Smallest repair: add a short plain gloss of five-run consistency, add a tooltip for full deferral, and mention the reported false-certification cap.
capping calibration false-certification rate at 0.00%-3.50%
date — pass: originalPublished (2026-11-20) matches the arXiv v1 submission date. The feed date of 2026-11-23 is later and was correctly not used.
[Submitted on 20 Nov 2026]
support — pass: Each claim matches the abstract: the training-free three-tier protocol, the limits of token probabilities and self-reported confidence, the masked 4B scoring, the MIRA-v2 98.91% result with about 80% compute saved, CDM escalation, and full deferral for the other cohorts. Saying MIRA-v2 reached the target is consistent with 98.91% against the 95% target line. The limitations and the question avoid extrapolating to other settings.
MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute
media — pass: The selected media is the verified direct arXiv abstract page for this paper, which is the most direct access to the source.
Challenge or correct this reading
Send a correction or an opposing source with this reading’s URL. Disagreement and uncertainty can remain unresolved.
arXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.
Explore arXivarXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.
Explore arXiv