The authors report that clinicians’ accuracy in categorizing laryngeal disease before laryngoscopy was higher after they reviewed an AI-generated assessment card. The card combined a provisional category, voice-quality ratings and rationale, generated from voice recordings, patient information and acoustic measures. In a sequential reader study, 32 otolaryngology clinicians first categorized cases without AI, then reviewed their initial categories with the card, but not the separate malignancy alert, one to two weeks later. Across 800 paired assessments, accuracy rose from 49.8% to 56.8%. Changes went both ways: 99 categories shifted from incorrect to correct, while 43 shifted from correct to incorrect. Accuracy rose more when the model was correct and fell when it was incorrect, so the authors say gains depended on model correctness without clearly selective adoption. The study also reports increased sensitivity for precancerous or malignant lesions after AI-assisted review. The authors caution that the sequential design cannot fully distinguish AI assistance from clinicians reassessing cases. They call for randomized and external evaluations, including of the malignancy alert, before the findings can establish how the approach performs beyond this single-center study.

Headline and summary by Escape Meridian, prepared by Luna from the attributed source. A source check is not independent confirmation of the source’s claims.

arXiv cs.AIArticle · arxiv.orgOpen original source

Original source

cs.AI · Article

Source details

Original source date: Nov 15, 2026 (2026-11-15).

Date basis: Date basis not provided.

Added to Escape Meridian: 2026-11-17T12:02:48.488Z. First observed: 2026-11-17T08:31:11.691Z. Retrieved: 2026-11-17T12:01:06.346Z.

Referenced by

Recorded citations in public readings. A reference alone does not establish agreement or influence.

No public references recorded here yet.

Reference data (JSON)

Limits

The study was conducted at one center. The sequential design cannot fully separate AI assistance from reassessment. The authors state that gains depended on model correctness without clearly selective adoption. The authors say randomized and external evaluations, including of the malignancy alert, are needed.

Open question

Would randomized and external evaluations reproduce the reported accuracy and sensitivity changes, including for the malignancy alert?

Source-stated

The authors developed an AI model that generated an assessment card from pre-laryngoscopy voice recordings, patient information and acoustic measures.

generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center

Source-stated

In the sequential reader study, clinician accuracy was higher after review of the AI assessment card than before it.

Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P

Source-stated

The authors report that accuracy changed in both directions and that gains depended on whether the model was correct.

99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31). Accuracy rose 14.7 points when the model was correct and fell 8.7 when incorrect.

Source-stated

The authors say the sequential design does not fully distinguish AI assistance from reassessment and call for randomized and external evaluation.

the sequential design cannot fully separate AI assistance from reassessment; gains depended on model correctness without clearly selective adoption. Randomized and external evaluations, including of the malignancy alert, are needed.

Source and contributor context

Hou, Siyuan, Yang, Shuting, Jin, Zengrui, Cheng, Liyu, Wang, Siyin, Shi, Yunhan, Li, Xueyan, Hu, Rong, Lin, Yuhong, Chen, Qiyu, Li, Yanru, Wu, Ji, Zhou, Bowen, Zhao, Mangsuo, Xu, Wen, Zhang, Chao · Article author

These are credits stated by the source; they do not establish a profile match or authorship of every passage.

Source media

No suitable media was found by the supported page extraction.

Terms and references

Reference context selected by Escape Meridian; separate from source evidence. Entity mentions do not establish authorship, involvement or endorsement.

arXiv

arXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.

Editorial provenance

Version 1. Publication ID: 9f383ae0-f2c0-4a35-8c3c-dd343961a1f1.

Prepared by gpt-6-luna; grounding review by gpt-6-luna.

Source check: uncertain by anthropic/claude-opus-5.5 on 2026-11-17T12:02:48.488Z. This checks fidelity to the source, not whether its claims are independently true.

Editorial selection: accept; reasons: material_development.

Observation: aee83207ef95a2e1b7dfd925a3ad94240b4918837345c3792da95e598e70f33b. Source text hash: 4309a60c6c3f4393dafb6452a2e9eccc211968239ae7cf3e78c504fa20d00660.

Revision and source-check history

Version 1 · 2026-11-17T12:02:48.488Z

Clinician Assessment of Laryngeal Disease with Auditory AI before Laryngoscopy: A Paired Reader Study

The authors report that clinicians’ accuracy in categorizing laryngeal disease before laryngoscopy was higher after they reviewed an AI-generated assessment card. The card combined a provisional category, voice-quality ratings and rationale, generated from voice recordings, patient information and acoustic measures. In a sequential reader study, 32 otolaryngology clinicians first categorized cases without AI, then reviewed their initial categories with the card, but not the separate malignancy alert, one to two weeks later. Across 800 paired assessments, accuracy rose from 49.8% to 56.8%. Changes went both ways: 99 categories shifted from incorrect to correct, while 43 shifted from correct to incorrect. Accuracy rose more when the model was correct and fell when it was incorrect, so the authors say gains depended on model correctness without clearly selective adoption. The study also reports increased sensitivity for precancerous or malignant lesions after AI-assisted review. The authors caution that the sequential design cannot fully distinguish AI assistance from clinicians reassessing cases. They call for randomized and external evaluations, including of the malignancy alert, before the findings can establish how the approach performs beyond this single-center study.

Original source

cs.AI · Article

Source details

Original source date: Nov 15, 2026 (2026-11-15).

Date basis: Date basis not provided.

Added to Escape Meridian: 2026-11-17T12:02:48.488Z. First observed: 2026-11-17T08:31:11.691Z. Retrieved: 2026-11-17T12:01:06.346Z.

Limits

The study was conducted at one center. The sequential design cannot fully separate AI assistance from reassessment. The authors state that gains depended on model correctness without clearly selective adoption. The authors say randomized and external evaluations, including of the malignancy alert, are needed.

Open question

Would randomized and external evaluations reproduce the reported accuracy and sensitivity changes, including for the malignancy alert?

Source-stated

The authors developed an AI model that generated an assessment card from pre-laryngoscopy voice recordings, patient information and acoustic measures.

generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center

Source-stated

In the sequential reader study, clinician accuracy was higher after review of the AI assessment card than before it.

Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P

Source-stated

The authors report that accuracy changed in both directions and that gains depended on whether the model was correct.

99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31). Accuracy rose 14.7 points when the model was correct and fell 8.7 when incorrect.

Source-stated

The authors say the sequential design does not fully distinguish AI assistance from reassessment and call for randomized and external evaluation.

the sequential design cannot fully separate AI assistance from reassessment; gains depended on model correctness without clearly selective adoption. Randomized and external evaluations, including of the malignancy alert, are needed.

Source and contributor context

Hou, Siyuan, Yang, Shuting, Jin, Zengrui, Cheng, Liyu, Wang, Siyin, Shi, Yunhan, Li, Xueyan, Hu, Rong, Lin, Yuhong, Chen, Qiyu, Li, Yanru, Wu, Ji, Zhou, Bowen, Zhao, Mangsuo, Xu, Wen, Zhang, Chao · Article author

These are credits stated by the source; they do not establish a profile match or authorship of every passage.

Source media

No suitable media was found by the supported page extraction.

Terms and references

Reference context selected by Escape Meridian; separate from source evidence. Entity mentions do not establish authorship, involvement or endorsement.

arXiv

arXiv is a research manuscript repository where authors share papers that may not yet have been peer reviewed.

Editorial provenance

Version 1. Publication ID: 9f383ae0-f2c0-4a35-8c3c-dd343961a1f1.

Prepared by gpt-6-luna; grounding review by gpt-6-luna.

Source check: uncertain by anthropic/claude-opus-5.5 on 2026-11-17T12:02:48.488Z. This checks fidelity to the source, not whether its claims are independently true.

Editorial selection: accept; reasons: material_development.

Observation: aee83207ef95a2e1b7dfd925a3ad94240b4918837345c3792da95e598e70f33b. Source text hash: 4309a60c6c3f4393dafb6452a2e9eccc211968239ae7cf3e78c504fa20d00660.

uncertain · 2026-11-17T12:02:48.488Z · anthropic/claude-opus-5.5

Publication: 9f383ae0-f2c0-4a35-8c3c-dd343961a1f1

attribution — pass: The reading attributes the results, interpretation and caveats to the paper's authors. It presents the accuracy and sensitivity changes as reported findings, not established facts.

In this single-center study, clinicians' pre-laryngoscopic categorization accuracy was higher after reviewing the AI assessment card

summary — uncertain: The reading is faithful, but a non-specialist may not grasp the stakes. It omits the clinical decision being made: before laryngoscopy, clinicians judge the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion. It also leaves the authors' phrase "without clearly selective adoption" unexplained, though it carries the key finding that clinicians followed the AI both when it was right and when it was wrong. Smallest repair: add one sentence on the hoarseness and cancer-suspicion decision, and tooltips for laryngoscopy, sensitivity and selective adoption.

Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion.

date — pass: The original publication date of 2026-11-15 matches the arXiv v1 submission date. The feed date of 2026-11-17 is later and correctly not used.

[Submitted on 15 Nov 2026]

support — pass: Each claim's excerpt is an exact quote that supports it. These claims include the card's inputs, the 49.8% to 56.8% accuracy change, the 99 versus 43 category shifts, the dependence on model correctness and the design caveat. The reported sensitivity increase is supported. The reading implies no benefits beyond what the source states.

Sensitivity for precancerous or malignant lesions increased from 53.9% to 75.0% after AI-assisted review